2SK 2SK-P1 Series Water Ring Vacuum Pump
The 2SK Series Two-Stage Water Ring Vacuum Pump and 2SK-P1 Series Double Stage Water Ring Atmospheric Ejector Pump Unit are used to suction air and other non-corrosive, water-insoluble gases that do not contain solid particles, in order to achieve a high vacuum within a closed container.
- The 2SK two-stage water ring vacuum pump offers exceptional performance with high vacuum levels and significant pumping speeds in high vacuum conditions.
- Its compact design allows for easy maintenance.
- This pump is versatile, capable of extracting a variety of gases, including those containing steam, flammable or explosive elements, as well as small amounts of dust and liquid.
- Utilizing primarily water as the working medium ensures low maintenance costs.
- It is also designed to operate effectively in more challenging environments.
丨Applications:
It is widely used in the textile, chemical, pharmaceutical, metallurgy, and electronics industries for processes such as vacuum evaporation, vacuum concentration, vacuum rehydration, vacuum impregnation, vacuum drying, and vacuum smelting. This product features high vacuum levels, significant pumping speeds in high vacuum ranges, and a compact structure, along with reliable operation and easy maintenance.
丨2SK Series Main Technical Parameter Table
|
Model |
Inspiratory Volume (m3/min) |
Ultimate Vacuum |
Power (kW) |
Speed (r.p.m) |
Water Consumption (L/min) |
Weight (kg) |
||
|
Max |
Suction pressure is -0.093MPa |
mmHg |
MPa |
|||||
|
2SK-1.5 |
1.5 |
0.9 |
-730 |
-0.097 |
4 |
1450 |
10~15 |
140 |
|
2SK-3 |
3 |
2 |
-735 |
-0.098 |
7.5 |
1450 |
15~20 |
180 |
|
2SK-6 |
6 |
4 |
-735 |
-0.098 |
15 |
1450 |
25~35 |
250 |
|
2SK-12 |
12 |
8 |
-735 |
-0.098 |
22 |
970 |
40~50 |
400 |
|
2SK-20 |
20 |
14 |
-735 |
-0.098 |
45 |
740 |
60~80 |
550 |
|
2SK-30 |
30 |
20 |
-735 |
-0.098 |
55 |
740 |
70~90 |
700 |
丨2SK-P1 Series Atmospheric Jet Pump Unit
|
Model |
m3/min Pumping speed |
(MPa) Ultimate pressure (mmHg) |
Motor power (KW) |
Speed (r.p.m) |
Flow of supplying water (I/min) |
|
|
When suction pressure is 30 torr (-730 mmHg) |
When suction pressure is 20 torr (-740 mmHg) |
|||||
| 2SK-1.5P1 | 1.05 | 0.9 | -0.099 (-750) | 4 | 1450 | 10~15 |
| 2SK-3P1 | 2.1 | 1.8 | -0.099 (-750) | 7.5 | 1450 | 15~20 |
| 2SK-6P1 | 4.2 | 3.6 | -0.099 (-750) | 15 | 1450 | 25~35 |
| 2SK-12P1 | 8.4 | 7.2 | -0.099 (-750) | 22 | 970 | 40~50 |
| 2SK-20P1 | 14 | 12 | -0.099 (-750) | 37 | 740 | 60~80 |
| 2SK-30P1 | 21 | 18 | -0.099 (-750) | 55 | 740 | 70~90 |
The values in the table are obtained under the following conditions:
- Water temperature: 15°C, air temperature: 20°C, gas relative humidity: 70%, atmospheric pressure: 1013 mbar (760 mmHg)
- The water supply amount is based on a suction vacuum of -400 mmHg, with the ultimate vacuum potentially exceeding this value.
- The deviation in pumping capacity does not exceed ±10%.